Emulex Lpe12000 Drivers
Dell Update Package for updating firmware on the Emulex Network and Fibre Channel adapters Search. Driver Details. Choose another product. The driver information is up-to-date. To view all drivers for your OEMR R310, go to Drivers and downloads. Emulex Network and Fiber Channel Adapter Firmware. Dell Update Package for updating. Emulex network adapters are high-performance adapters that consolidate traffic for networking, Fibre Channel and FCoE storage. Includes FCoE Converged Network Adapter (CNA) and Host Bus Adapters (HBA). Visit Dell.com to learn more. Emulex Drivers Version 10.2 for VMware ESXi User Manual P010087-01A Rev. Introduction Supported Guest Operating Systems 9 Supported Guest Operating Systems The Emulex driver supports the following guest operating systems: CentOS 5.x CentOS 6.x RHEL 5.x RHEL 6.x RHEL 7.x SLES 11.x Windows Server 2008 R2 Windows Server 2012. Firmware for HP Branded 8Gb Emulex HBAs and Mezz Cards. By downloading, you agree to the terms and conditions of the Hewlett Packard Enterprise Software License Agreement. Note: Some software requires a valid warranty, current Hewlett Packard Enterprise support contract, or a license fee. Streamlined installation and management, plus unrivaled scalability and industry-leading virtualization support make the Emulex 8Gb Fibre Channel single-port and dual-port host bus adapters ideal solutions for enterprise and mixed-OS environments. With powerful management tools, they deliver maximum performance in the widest range of applications and environments. Mar 08, 2011 Firmware for FC2242 (A8003A) HBA and the Emulex LPe1105-HP 4Gb c-class Mezzanine HBA. By downloading, you agree to the terms and conditions of the Hewlett Packard Enterprise Software License Agreement. Note: Some software requires a valid warranty, current Hewlett Packard Enterprise support contract, or a license fee.
- Emulex Lpe12000 Driver Vmware
- Emulex Driver Download
- Emulex Lightpulse Hba Driver
- Emulex Lpe12000 Drivers License
- Emulex Drivers For Windows
- Emulex Lpe12000 Driver Download
Printable version |
|
HP maintains the SPOCK website as the primary source of detailed information about HP storage product configurations, including operating system, software, and firmware version support. For the latest information about storage array support, see the HP SPOCK website at http://www.hp.com/storage/spock. You must sign up for an HP Passport to enable access.
Some HBA/CNA download kits include a readme.txt
file that may contain additional information about installing firmware and drivers, plus enhancements and fixes in the current release. Information in the readme.txt
file supersedes this and other HP Emulex documents.
This section lists the HBAs and CNAs that are supported on ProLiant and Integrity servers. Although CNAs have FCoE, NIC, and iSCSI functionality, this document addresses FCoE functionality only.
Table 1, “Supported CNAs and server LOMs” describes the CNAs and server LOMs (LAN on motherboard) supported on servers running Windows, Linux, VMware, and Citrix operating systems.
NOTE: The Restriction of Hazardous Substances Directive (RoHS) is a European Union directive that restricts the use of certain hazardous materials in the manufacture of electronic and electrical equipment. |
Table 1 Supported CNAs and server LOMs
Model | Windows Server 2003 | Windows Server 2008 | Windows Server 2012 | Linux | VMware | Citrix[1] |
---|---|---|---|---|---|---|
CNA | ||||||
HP CN1100E Dual Port Converged Network Adapter (BK835A) | • | • | • | • | • | • |
HP CN1000E Dual Port Converged Network Adapter (AW520A/AW520B)[2] | • | • | • | • | • | • |
HP NC551m Dual-port FlexFabric 10-Gb Converged Network Adapter (580151-B21) | • | • | • | • | • | • |
HP NC553m Dual-port FlexFabric 10-Gb Converged Network Adapter (613431-B21) | • | • | • | • | • | • |
HP FlexFabric 10Gb 2-port 554M Adapter (647590-B21) | — | • | • | • | • | • |
Server LOM | ||||||
Embedded NC551i Dual-port FlexFabric 10-Gb Converged Network Adapter | • | • | • | • | • | • |
Embedded NC553i Dual Port FlexFabric 10-Gb Converged Network Adapter | • | • | • | • | • | • |
HP FlexFabric 10Gb 2-port 554FLB Adapter (647586-B21) | — | • | • | • | • | • |
HP FlexFabric 10Gb 2-port 554FLR-SFP+ Adapter (629142-B21) | — | • | • | • | • | • |
Legend: • = supported; — = not supported | ||||||
[1] Support is limited to Citrix XenServer 5.6 with lpfc driver 2.102.485 and 8.2.8.47.7p driver disk. For more information or to download the driver update, see the Citrix Knowledge Center website at http://support.citrix.com/article/CTX128028. [2] The AW520B is the new RoHS-compliant CNA that replaces the AW520A. These models are functionally equivalent and interchangeable. |
Table 2, “Supported HBAs and mezzanine cards” describes the HBAs and mezzanine cards supported on servers running Windows, Linux, VMware, and Citrix operating systems.
Table 2 Supported HBAs and mezzanine cards
Model | Windows Server 2003 | Windows Server 2008 | Windows Server 2012 | Linux | VMware | Citrix |
---|---|---|---|---|---|---|
16-Gb HBAs | ||||||
HP SN1000E 16Gb Fibre Channel Host Bus Adapter—single port (QR558A) | — | • | • | • | • | • |
HP SN1000E 16Gb Fibre Channel Host Bus Adapter—dual port (QR559A) | — | • | • | • | • | • |
8-Gb HBAs and mezzanine cards | ||||||
HP LPe1205A 8Gb FC HBA for BladeSystem c-Class (659818-B21)[1] | — | • | • | • | • | • |
HP StorageWorks LPe1205–HP 8-Gb FC Mezzanine Card HBA (456972–B21)[2] | • | • | • | •[3] | • | • |
HP 81E 8-Gb PCI-X HBA (AJ762A/AJ762B)[3][4] | • | • | • | • | • | • |
HP StorageWorks 82E 8-Gb PCI-X Dual Channel HBA (AJ763A/AJ763B)[3][5] | • | • | • | • | • | • |
HP PCIe 1-port 8-Gb Fibre Channel HBA (AH402A) | •[6] | •[6] | — | — | — | — |
HP PCIe 2-port 8-Gb Fibre Channel HBA (AH403A) | •[6] | •[6] | — | — | — | — |
4-Gb HBAs and mezzanine cards | ||||||
HP StorageWorks LPe1105–HP 4-Gb FC HBA for HP c-Class BladeSystem (40362-B21) | • | • | • | • | • | • |
HP FC2142SR 4-Gb PCIe FC HBA (A8002A/A8002B)[7][8] | • | • | • | • | • | • |
HP FC2242SR 4-Gb PCIe dual port FC HBA (A8003A/A8003B)[9] | • | • | • | • | • | • |
Legend: • = supported; — = not supported | ||||||
[1] The HP LPe1205A is supported in Gen8 blade servers only. [2] The LPe1205 is supported with most G6 and later ProLiant blade servers with the exception of BL465G6 and BL495G6. [4] The AJ762B is the new RoHS-compliant HBA that replaces the AJ762A. These models are functionally equivalent and interchangeable. [5] The AJ763B is the new RoHS-compliant HBA that replaces the AJ763A. These models are functionally equivalent and interchangeable. [7] The FC2142 HBA is also supported on XW8400 and XW9300 workstations running Windows XP Professional (32-bit). [8] The A8002B is the new RoHS-compliant HBA that replaces the A8002A. These models are functionally equivalent and interchangeable. [9] The A8003B is the new RoHS-compliant HBA that replaces the A8003A. These models are functionally equivalent and interchangeable. |
Table 3, “Supported legacy HBAs and mezzanine cards” describes the Legacy HBAs and mezzanine cards supported on servers running Windows, Linux, VMware, and Citrix operating systems.
NOTE: The HBAs and mezzanine cards listed in Table 3, “Supported legacy HBAs and mezzanine cards” are supported; however, they are no longer available for purchase. |
Table 3 Supported legacy HBAs and mezzanine cards
Model | Windows Server 2003/2008 | Linux | VMware | Citrix |
---|---|---|---|---|
4-Gb HBAs | ||||
HP StorageWorks FC2143 4-Gb PCI-X FC HBA (AD167A) | • | • | • | • |
HP StorageWorks FC2243 4-Gb PCI-X dual port FC HBA (AD168A) | • | • | • | • |
2-Gb HBAs and mezzanine cards | ||||
HP StorageWorks 1050EX 2-Gb PCIe FC HBA (A7560A) | •[1] | — | — | — |
HP StorageWorks A7388A 2-Gb PCI-X FC HBA (A7388A) | • | — | — | — |
HP StorageWorks A7387A 2-Gb PCI-X dual port FC HBA (A7387A) | • | — | — | — |
HP StorageWorks FCA2404DC 2-Gb PCI-X dual port FC HBA (323264-B21) | •[1] | — | — | — |
HP StorageWorks FCA2404 2-Gb PCI-X FC HBA (305573-B21) | •[1] | — | — | — |
HP Emulex-based BL20p 2-Gb PCI-X FC mezzanine card (394757-B21) | •[1] | — | — | — |
HP Emulex-based BL25/30/35/45p PCI-X FC mezzanine card (394588-B21) | •[1] | — | — | — |
HP StorageWorks AB467A 2-Gb 1-port FC HBA | •[2] | — | — | — |
HP StorageWorks AB466A 2-Gb 2-port FC HBA | •[2] | — | — | — |
Legend: • = supported; — = not supported | ||||
[2] Supported on Windows Integrity servers only |
Emulex CNAs, HBAs, and LOMs are supported on HP servers that:
Support the Linux, Windows, VMware, and Citrix operating systems listed on the HP website:
Support the servers listed on the HP website:
Support B-series, C-series, M-series/McDATA, and H-series switch products. For the latest information, see the HP support website at http://welcome.hp.com/country/us/en/support.html and the HP SAN Design Reference Guide at http://www.hp.com/go/sdgmanuals.
For information about the supported servers for the CNAs, see the CNA QuickSpecs.
Before you perform CNA or HBA updates, you must do the following:
Ensure that the system is running one of the operating system versions listed in HBA Software Support Matrices, available at the SPOCK website http://www.hp.com/storage/spock.
You must sign up for an HP Passport to enable access.
See the HP server PCI slot specifications to determine if your server is compatible with the CNA or HBA.
If you are installing the Linux operating system for the first time, load the operating system before you download and install the Linux CNA/HBA/LOM driver from the HP website:
For information on installing CNAs, see HP Emulex Converged Network Adapter Installation Guide. For information on installing HBAs, see HP Emulex Fibre Channel Host Bus Adapter and Driver Installation Guide. To download either of these guides:
Go to http://www.hp.com/support/manuals.
Using the HP model number as your guide, enter the adapter model number in the Search products box, and then click >>.
IMPORTANT: If you have both CNAs and Fibre Channel HBAs installed in your Linux system, you must install and use the CNA drivers. If you have both CNAs and Fibre Channel HBAs installed in your Windows system, you must install the FCoE CNA driver and the Fibre Channel HBA driver. |
This section describes how you can obtain the latest information about supported operating systems and software.
For the latest information about supported HBAs, CNAs, LOMs, and mezzanine cards listed by operating systems, see the HP SPOCK website at:
You must sign up for an HP Passport to enable access. From the web page, click HBA Software Support Matrix, and then select your operating system.
This section contains information about CNA and HBA support for Linux.
For HBA Linux support information, see http://h18006.www1.hp.com/storage/saninfrastructure/hba.html.
For CNA Linux support information, see the HP Converged Network Adapters website at http://h10010.www1.hp.com/wwpc/us/en/sm/WF05a/12169-304608-4109633-4109633-4109633-4118472.html?dnr=1.
For more information, see the readme.txt
file packaged with the kit.
Determining the CNA/HBA driver and firmware versions in Linux |
You can use OneCommand Manager or HBAnyware to view a list of CNA/HBA driver and firmware information.
NOTE: Newer versions of the HBA driver use Emulex OneCommand software for HBA management and older versions of the driver use Emulex HBAnyware software. To determine the HBA management software needs for your configuration, see HBA Software Support Matrix available on the HP SPOCK website at http://www.hp.com/storage/spock. You must sign up for an HP Passport to enable access. |
This section describes CNA/HBA support for Windows.
CNAs/HBAs/LOMs are supported on ProLiant servers with Enterprise, Standard, Storage Server, and Datacenter versions of the following:
CNAs/LOMs on Windows:
Windows Server 2003 x86, x64 – R2 SP2
Windows Server 2008 W32 – SP2 and Windows Server 2008 x64 – SP2, R2: SP2
Windows Server 2012
HBAs on Windows:
Windows Server 2003 x86 – SP1, R2, SP2 (32-bit) (STORport and SCSIport)
Windows Server 2003 x64 – SP1, R2, SP2 (64-bit) (STORport only)
Windows Server 2003, IA64 – SP1, SP2
Windows Server 2008 W32 – SP2
Windows Server 2008 x64 – SP2, R2
Windows Server 2008, IA64 – SP2, R2
Windows Server 2012
HP supports the use of Windows and Linux as a guest operating system on VMware ESX versions 4.x and 5.x. For information on VMware driver support, see the HP Server Virtualization website at https://h20392.www2.hp.com/portal/swdepot/displayProductsList.do?category=SVIRTUAL. Windows and Linux Fibre Channel HBA drivers are not used on the virtual operating system.
To ensure that your HBA/CNA is supported by HP and VMware, see VMware Compatibility Guide at:
NOTE: VMware is not supported on the IA64 architecture. |
HP supports the Citrix Hypervisor. For more information, see the HP Virtualization with Citrix website:
NOTE: HP does not support HP Emulex Fibre Channel or CNA FCoE products on Citrix XenServer 5.6 FP1. HP Emulex CNAs only support NIC functionality of Citrix XenServer 5.6 FP1. For more information, see the Citrix Knowledge Center article at: For Fibre Channel and FCoE support, you must upgrade to Citrix XenServer 5.6 SP2 or later. |
This section describes restrictions, notes, and issue workarounds for Emulex CNA/HBA adapters.
The notes in this section apply to all operating systems.
HP Emulex CNA connected to ports on HP P9500 or XP20000/24000 storage arrays can result in channel adapter (front-end port) blockades |
This blocked condition results in a loss of access to storage by the paths provided through the channel adapter (CHA) to all connected hosts. This issue can occur with HP Emulex CNA firmware earlier than 4.1.450.14. To prevent this issue, you must ensure that the HP Emulex CNA firmware version is 4.1.450.14 or later. HP recommends that you install HP Emulex CNA firmware 4.1.450.16 or later.
When updating firmware on an Emulex adapter, all Emulex adapters installed in the server must be enabled. One or more disabled adapters or adapter ports will cause the firmware update to fail.
The HP LPe1205A BIOS does not auto-negotiate to the highest possible speed when the adapter installed in a BL465 Gen8 server. When searching for targets, the Boot BIOS negotiates to the next-highest speed (4 Gb for 8 Gb connections or 2 Gb for 4 Gb connections). When the operating system driver comes online, the link re-negotiates to the expected speed.
The SN1000E 16 Gb HBA does not support 2 Mb transfer sizes.
You can use the server ROM-Based Setup Utility (RSBU) to view or change the CNA personality (iSCSI or FCoE).
When a CNA is configured for FCoE, you must enable the network boot on all NIC ports in order to detect LUNs. Use the server RBSU Embedded NICs menu to enable the network boot. In a blade environment, if you configure FCoE with Vitual Connect, VC enables network boot in the RBSU automatically.
HP Fibre Channel Enablement Kit and OneCommand Manager Application interoperability |
The HP Fibre Channel Enablement Kit and OneCommand Manager both install API libraries and can be used individually. For those configurations using both kits, HP recommends that you install the Enablement Kit before you install OneCommand Manager. When uninstalling, HP recommends that you remove OneCommand Manager before you remove the Enablement Kit.
Emulex Lpe12000 Driver Vmware
The CN1000E maximum supported Ethernet Jumbo Packet frame size is 8192 bytes.
The CN1000E maximum supported optical cable length is 40 meters.
When using a C-series Converged Network Switch (HP Nexus 5000) with the HP Virtual Connect FlexFabric 10-Gb/24-port module, NPIV must be enabled on the C-series switch.
DL16x and DL18x Servers require extra time to boot from SAN.
When the CN1000E is used as the boot device in a DL16x or DL18x server, the server can pause for approximately 90 seconds when it is expected to start booting from the hard disk. After this delay, the boot process resumes as expected.
Update DL/SL100-series BIOS before installing CN1000E |
Before installing an HP CN1000E into a DL/SL100-series server, you must upgrade the server BIOS to 2010.02.04 or later. The BIOS is available for download from the HP Download Drivers and Software website:
HP recommends that you implement zoning by CNAs/HBAs, as described in the HP SAN Design Reference Guide, available at:
Emulex Driver Download
HP ProLiant DL380 (G4) servers must have System ROMPaq firmware 4.05 P51-08/16/2005 or later to be compatible with the FC2142SR and FC2242SR. Failure to use this ROMPaq version can cause the HBAs to hang during the power-on self-test (POST). For more information, see the HP website:
This section provides information about Linux and CNAs/HBAs.
RHEL6.4 Inbox online firmware update for CNAs using ethtools |
You must use ethtools
to perform an online CNA firmware update while running RHEL6.4 Inbox. To do this:
Emulex Lightpulse Hba Driver
Copy the latest firmware image
(.ufi)
from http://www.hp.com/support/downloads to the/lib/firmware
directory:# cp oc1x-4.x.xxx.xx.ufi /lib/firmware
Start the update process:
# ethtool -f eth<X> oc1x-4.x.xxx.xx 0
Reboot the system to enable the new firmware image to take effect.
There is no management support for CNAs using the OneCommand Management Utility for RHEL6.4 Inbox at this time.
Fibre Channel HBAs do support OneCommand for RHEL6.4 Inbox.
In a BFS configuration, a bindings file becomes out-of-sync between the copy in /var/lib/multipath
and a copy in the initrd
image the server uses during boot.
A workaround is documented in the Native Linux Device-Mapper Multipath for HP Storage Disk Arrays reference guide, available at http://spock.corp.hp.com/utility/document.aspx?docurl=Shared%20Documents/an/solutions_linux/Device_Mapper_Multipath_RG_2012_02_21.pdf
SCSI reset status incorrectly reported in /var/log/messages |
An SLES 11 SP1 x64 system with an lpfc driver 8.5.3.44 can incorrectly report SCSI resets status in /var/log/messages similar to the following:
Aug 9 12:01:12 xyz kernel: [ 6783.419080] lpfc 0000:a1:00.0: 4:(0):0714 SCSI layer issued Bus Reset Data: x0
You can ignore this message.
Firmware download in SLES 10 SP3 can cause the system to hang.
When downloading firmware to the CNA in SLES 10 SP3 using OneCommand Manager or hbacmd
, the download may complete but cause the system to become unresponsive or hang. Though the firmware download is successful, a hard reboot of the server may be required to enable the new firmware.
ReiserFS file systems can exhibit unexpected behavior under heavy loads. HP recommends that you use either the xfs
or ext3
file system. For up-to-date recommendations, see the Novell website:
HP recommends that you use the ext3
file system in high availability (HA) environments. For information on how to use other Linux file systems in an HA environment, see SLES 11 Administration Guide, available at the Novell website http://www.novell.com/documentation/sles11 and the Red Hat Deployment Guide, available at the Red Hat website http://www.redhat.com.
For information on the differences between ext2
and ext3
, see the operating system documentation.
For the MSA2000 family of disk arrays:
The minimum required firmware is
J200P24-01
.Creating virtual disks (vdisks) online or offline without volumes during the virtual disk creation process is not supported. You must create at least one volume during the virtual disk creation.
MultiPulse is not supported. For information about multipathing support, see the HP Device Mapper documentation.
The Emulex MultiPulse 2.2.22, 2.2.38, 2.2.39, and 2.2.44 drivers support active/active storage arrays only.
If using MultiPulse 2.2.x, you can have a maximum of eight physical paths to a LUN. More than eight paths can cause a failure.
MultiPulse can coexist with multipathing products such as the Emulex failover driver and Secure Path. However, MultiPulse works only with Emulex-based HBAs; it will not configure multiple paths for other HBAs in the system.
Because the order in which a switch reports Fibre Channel ports to a name server can vary, the order in which LUNs are discovered can vary between system boots.
HP recommends that you use the udev
utility to ensure that the name of a device does not change between system boots. For more information, see the udev website:
XP LUNs presented to Linux hosts must start with LUN 0.
A maximum of 10 targets are supported in a BFS zone.
On an sx2000 system with the default logging level, a call trace may appear in the /var/log/messages
file during failover events.
When running the scsi_info
command on older XP arrays, such as XP1024/128, you may see output similar to that shown in the following example. Ignore the error, and note that the WWN is not all zeros.
The XP array returns inquiry data that differs slightly from that returned by EVA or MSA arrays.
[root@coco /]# scsi_info /dev/sdal SCSI_ID='4,0,8,0':
VENDOR='HP':MODEL='OPEN-
E':FW_REV='5005':WWN='0000000000000000':LUN='5235303020303030-3130353930203030'
[root@coco /]# scsi_info /dev/sdam
SCSI_ID='4,0,8,1':VENDOR='HP':MODEL='OPEN-
E':FW_REV='5005':WWN='0000000000000000':LUN='5235303020303030-3130353930203030'
[root@coco /]# scsi_info /dev/sdan
SCSI_ID='4,0,9,0':VENDOR='HP':MODEL='OPEN- 3':FW_REV='2114':WWN='03000000002018e9':LUN='5234353120303030-3330313033203030'
[root@coco /]# scsi_info /dev/sdao SCSI_ID='4,0,9,1':VENDOR='HP':MODEL='OPEN-
3':FW_REV='2114':WWN='0b00000000600000':LUN='5234353120303030-3330313033203030'
Installing PSP 7.91/92 causes fibreutils
to downgrade. Reinstall fibreutils rpm
from the downloaded kit.
Example:
#rpm –fvh fibreutils.<
version
>.linux.<
arch
>.rpm
When an EVA4400 with embedded switch is configured in a heterogeneous SAN, HP recommends that you use a text editor to edit the HBA configuration file etc/modprobe.conf
.
options lpfcmpl mpl_hbeat_tmo_busy=0
Save the file, and then run the make_initrd
script.
# /opt/hp/hp-lpfc/make_initrd
Reboot your server with the correct initrd
.
Dynamic LUN addition and removal are supported. However, the ability to dynamically add a new LUN (or a LUN that has been previously removed) using the LUN number of a previously removed LUN is not supported. Dynamic target addition, which is defined as adding a new Fibre Channel target (such as adding a new storage array) to a SAN, is also not supported. The ability to present the new target to a Fibre Channel HBA, and then prompt the operating system to do an online scan (such as using the hp_rescan
utility that comes with fibreutils
) is not supported with the Emulex failover driver (MultiPulse). If you add a new Fibre Channel target to a host server, you must reboot that server.
This section describes information about using Windows and CNAs/HBAs.
Configuring Virtual Fibre Channel in Windows 2012 Hyper-V |
When configuring Virtual Fibre Channel in Windows 2012 Hyper-V, all ports on the Converged Network Adapter must have NPIV enabled.
The 64 Bit DMA addressing feature is not supported in Emulex Windows FC/FCoE drivers at this time.
If the Windows operating system crashes on a Gen8 server, a memory.dmp
file might not get written to disk due to a Windows driver issue.
Before you build a Windows 2003 SP2 operating system in a boot from SAN environment, you must install one of the following drivers:
For 64 bit systems, install 233008_BFS_x64_FCoE, available at:
For 32 bit systems, install 233008_BFS_x32_FCoE, available at:
After the operating system is built, install the Microsoft STORport storage driver available at http://support.microsoft.com/?id=932755, and then update to the latest driver supported by HP.
Systems running Windows Server 2008/Windows Server 2008 Service Pack 2 require KB hotfix 976748 to be installed before installing Microsoft Device Specific Module (MS DSM) as a multipath solution. For more information, see the Microsoft Support website:
HP EVA MPIO DSM 4.00.00 prevents BFS on systems running Windows 2003 if there are three or more paths enabled.
Windows driver fails to log back into the Cisco Nexus 5000 switch after switch reboot.
Emulex Lpe12000 Drivers License
On Windows 2003 and Windows 2008, the link is not re-established when a Cisco Nexus 5000 switch is rebooted. The workaround is to use the Nexus Shutdown
and No Shutdown
CLI commands to bring the port back online.
STORport miniport driver installation restrictions |
If you are upgrading to the STORport miniport driver, consider the following:
The STORport miniport driver is supported on Windows 2003 SP1 and later.
Microsoft hotfix KB932755 must be installed before installing Multipath software.
If you are running Secure Path for Windows, you must upgrade to Secure Path 4.0c SP2 or later for Windows. STORport is not supported with earlier versions of Secure Path.
Integrity servers running WS2003 support Windows STORport driver 2.10x1 or earlier.
Emulex 2-Gb HBAs and mezzanine cards are not supported with WS2008 R2.
The following Smart Component issues may be observed during driver installation:
When using the Smart Component to install drivers, if the following message appears during reboot, ignore it and continue with the reboot procedure. No known issues have been observed in connection with the display of this message.
The application failed to initialize because the windows station is shutting down.
Downgrading to STORport driver Version 2.0 or later does not work when initiated via the Smart Component. To downgrade an HP-branded Emulex HBA:
Run the Smart Component containing the desired driver and extract the contents to a folder.
Run the STORport driver installer from the extracted folder using the default values. For example:
storportminiportcorekit_2-01a4
This removes the current driver before downgrading to the specified driver version.
When using the Smart Component to install drivers, the following message may appear during reboot:
There was a problem installing this hardware. This device is not working properly because Windows cannot load the drivers required for this device. (Code 31)
Uninstall and then reinstall your device.
If the above message appears, click and continue with the reboot procedure. Do not reply to Microsoft. No known issues have been observed in connection with the display of this message.
In a direct connect environment, BFS fails after a second path is added to an EVA4000/6000/8000 running firmware 6.110.
BFS on c-Class blade servers fails on an active/passive MSA1000/1500 running firmware 5.20.
In BFS configurations where there are more than two Emulex HBAs in the same zone as the boot HBA, a crash-dump may not be generated due to a timeout condition when the boot HBA interacts with the non-boot HBAs. A workaround is to reconfigure the zoning such that the boot instance (for each path) is in its own zone separate from the other non-boot HBAs. In some cases, this also results in faster boot-up times.
When installing the OS to attached storage of the 403621-B21 LPe1105 mezzanine card in a VC environment through a Brocade switch, neither the target LUN nor the WWN for the boot controller are visible in the zone via the switch administrative tool. The workaround is to take note of the mezzanine card WWN when installing it into the system, or retrive it from the VC manager or EFI utility. Then manually enter the WWN into the desired zone on the switch when configuring the zone. Scan for targets and continue with normal installation steps to boot from the mezzanine card.
In a BFS configuration, the installed HBAs can display different names when viewed through the device manager. This is a cosmetic condition, not a functional issue.
When you select the
Load Driver
option during the operating system build of a Windows 2008 server in a BFS configuration, a multiple entry of the Emulex driver is displayed. If multiple types of HBAs are displayed, select the first entry before proceeding.See FCoE BFS build requirement.
This section describes information about using VMware and CNAs/HBAs.
OCM GUI on ESX COS servers does not display all SAN storage arrays |
The OCM GUI on ESX COS servers does not display all SAN storage arrays due to an issue with the communication path between the OCM GUI and ESX COS server.
Emulex Drivers For Windows
If this occurs, delete the affected server from the host inventory, and then add the server with CIM credentials (as a CIM server).
There is an issue when loading and running the elxcomcore rpm
on ESX COS servers. If you attempt to add the ESX host using the CIM interface via the Windows OCM GUI, the Windows OCM is unable to connect to SFCB server.
To avoid this issue, install the Emulex VMware COM provider on the ESX COS (4.1) server, and then use the Windows OCM GUI CIM interface to add the server.
Downloading CIM Provider for ESXi 5.0 and ESXi 5.1 |
Use the following links to download CIM Provider.
Emulex Lpe12000 Driver Download
ESXi 5.1—http:www.emulex.com/downloads/emulex/vmware/vsphere-51/management.html
ESXi 5.0—http:www.emulex.com/downloads/emulex/vmware/vsphere-50/management.html
HP is committed to providing documentation that meets your needs. To help us improve the documentation, send any errors, suggestions, or comments to Documentation Feedback (docsfeedback@hp.com
). Include the document title and part number, version number, or the URL when submitting your feedback.
February 2013